RFswitchATTstamp
RFswitchATT HANDOVER SIMULATOR – reconfigurable microwave switching matrix with frequency range from 500 MHz to 6000 MHz.

The RFswitchATT HANDOVER SIMULATOR unit is used to switch and attenuate RF signals between wireless devices. The most important innovative element of the device is the remote configuration of attenuators and switches settings. Thanks to this innovative solution a user is given the possibility to conduct RF devices tests while sitting at the office or being anywhere else. What is more, a user has the access to professionally equipped Wireless Systems Testing Labs without incurring high costs. Product include LAN software suite and supports automated scripting via API.

Technical specifications
Mode: Switching Switching & attenuation
Impedance: 50 Ω
Frequency range: from 500MHz to 6000MHz
Attenuation range: from 0 to 90 dB
Attenuation step: min 0.25dB
Insertion Loss: 25 dB max., 10dB@0dB attenuation 25 dB max., 13dB@0dB attenuation
Attenuation accuracy: ± 1.0dB@0-30dB att., ± 1.8dB@30-60dB att., ± 6.0@60-90dB att. ± 0.7dB@0-30dB att., ± 1.5dB@30-60dB att., ± 8.0@60-90dB att.
Switching speed: 10μs typ.
Input/Output VSWR: Max. 2.0:1, Typ. 1.4 Max. 2.0:1, Typ. 1.6
Isolation: 68dB 32dB
RF Input Power: 28dBm 31dBm
RF connectors: N – female, SMA – female (front or rear chassis side)
RF port configurations: 2×2, 2×4, 4×4, 4×6, 6×6, 6×8, 8×8 other custom configurations available

Hardware & functional specifications
Controlled by IP application (WWW/API/SSH)
Remote Control – Ethernet (IP, 10/100 Mbps)
Optional Manual Control – 3-button keypad and LCD display
High-Quality 2U 19” rack cases aluminum chassis (desktop, mobile with handheld also available)
Power supply: 100-230VAC 50/60Hz (Optional 12VDC)
Optional Backup power supply – 1300mAh (about 2h runtime)
Operating Temperature: 0 ~ 40˚C
Operating Humidity: 10 ~ 90%
Weight: ~2.0 kg